LIVE VALVE Check Valve

Product Features

  • Closing time (dynamic response) is only a fraction of a second
  • Avoid or minimize pressure fluctuations in the pipeline
  • Suitable for high-pressure working conditions (PN50 - 725 psi)
  • No axial shaft design, eliminating the risk of axial disc jamming
  • Short end face spacing for easy installation
  • Excellent disc sealing performance
  • High erosion resistance of the axial disc
  • Corrosion-resistant material of the axial disc
  • Maintenance-free
  • A wide range of material options for various application scenarios
Request a Quote

PRODUCTS DETAILS

LIKE Valve LIVE VALVE Check Valve

LIKE: High Dynamic Response Check Valve

Product Features

  • Closing time (dynamic response) is only a fraction of a second
  • Avoid or minimize pressure fluctuations in the pipeline
  • Suitable for high-pressure working conditions (PN50 - 725 psi)
  • No axial shaft design, eliminating the risk of axial disc jamming
  • Short end face spacing for easy installation
  • Excellent disc sealing performance
  • High erosion resistance of the axial disc
  • Corrosion-resistant material of the axial disc
  • Maintenance-free
  • A wide range of material options for various application scenarios

Product Advantages

  • When the pump shuts down suddenly in an emergency, the LIKE check valve can reduce pressure fluctuations in the pipeline
  • Silent and non-impact check valve
  • Easy installation
  • Suitable for vertical, horizontal and inclined installation
  • Fast flow recovery

Application Scenarios

Specifically designed for turbine pump stations and auxiliary systems of nuclear power plants.

Technical Parameters

  • Size range: DN80 - DN1800 (3 inches - 72 inches)
  • Maximum working pressure:
  • DN80 - DN500: 50 bar (725 psi) at ambient temperature
  • DN600 - DN800: 25 bar (362 psi) at ambient temperature
  • DN900 - DN1000: 20 bar (290 psi) at ambient temperature
  • DN1200 - DN1800: 16 bar (232 psi) at ambient temperature
  • Temperature range: -10°C to +130°C (50°F to +266°F)
  • Flange adaptation standards:
  • EN 1092-1
  • ISO 2084
  • EN 1759
  • ANSI B16.5
  • ANSI B16-47 A
  • MSS SP44
  • AWWA C207
  • Other standards available upon request

DN1400 (56 inches) LIKE Installation

For details, please visit:

© 2020 LIKE Valve Company. All rights reserved.

Valve Body Type Description

  • DN80 - DN500 (3 inches - 20 inches): Wafer-type valve body
  • DN600 - DN1800 (24 inches - 72 inches): Flanged-type valve body

 LIVE VALVE Check Valve

Figure 1: Example of DN450 Wafer Check Valve

No.

Component Name (or Upstream Valve Body)

Description

1

Valve Body

- Integral precision casting<br>- The valve body flow channel is fully optimized and hydraulically tested by the fluid control laboratory to ensure rapid flow recovery<br>- The valve body coating meets the latest current standards

2

Arrow Mark

Directly cast on the valve body to ensure correct installation

3

Nameplate

Stainless steel material, including core product information

4

Axial Disc

- Multiple corrosion-resistant material options available<br>- The only moving part<br>- Mechanical performance advantages:<br>  * Low inertia, extremely short closing time, and small pressure fluctuations during closing<br>  * Perfect sealing performance<br>  * No noise during closing<br>  * Excellent resistance to impact and vibration<br>  * High erosion resistance<br>- Streamlined design to guide fluid and achieve automatic centering of the disc

5

O-ring

Ensure good sealing effect

6

Spring

Made of corrosion-resistant material

7

Back Plate (or Downstream Valve Body)

- Integral precision casting<br>- The valve body flow channel is fully optimized and hydraulically tested by the fluid control laboratory to ensure rapid flow recovery<br>- The valve body coating meets the latest current standards

8

Lifting Lug

Facilitate valve installation and transportation

 LIVE VALVE Check Valve

Figure 3: Cross-Section of Wafer Check Valve

Working Principle

Check valves installed in large water supply networks and water transmission pipelines of pump stations need to operate frequently. Statistical data shows that severe pressure fluctuations often result from the installation of inappropriate types of valves. For example, when the pump in the pump station shuts down, the fluid flow rate decreases and stops, followed by backflow (see Figures 4, 5). At this time, the valve closes under the action of the disc's gravity, the return spring, or the thrust of fluid backflow.

Experience and calculations show that backflow can occur in an extremely short time (1/100 second to 1/10 second). If the valve does not respond in time, it will close sharply under backflow conditions, leading to:

  • Violent impact of the disc on the valve seat, generating strong shock waves
  • Water hammer effect, causing pressure fluctuations

Shock waves and pressure fluctuations will cause stress impact on the equipment, which may lead to mechanical failures of valve components and pipelines.

If an air pressure water tank is installed in the system (see Figure 6), the above problems will be more prominent. At this time, backflow will occur rapidly in the short pipe between the water tank and the pump, so the valve must respond faster to avoid serious damage.

 LIVE VALVE Check Valve

Figures 4, 5, 6: Working Diagrams of Check Valve and Pump

Description of High Dynamic Response Check Valve

The characteristics of an ideal check valve can be summarized by the curve in Figure 7.

 LIVE VALVE Check Valve

Figure 7: Fluid Velocity-Time Curve

  • Vertical axis: Water flow velocity (m/s)
  • Horizontal axis: Time (second)
  • Key nodes:
  • t=0: Pump shutdown
  • t=t0: Water flow velocity drops to 0, and backflow starts (usually 1/100 second < t0 < 1/10 second)
  • t=t1: The check valve closing part seats, the backflow velocity is V1, backflow stops immediately, and the overpressure is proportional to the backflow velocity (V1)
  • An ideal check valve should close at t=t0

LIKE meets this requirement for the following reasons:

  • Short end face spacing, shortening the axial disc stroke
  • No axial shaft design, avoiding prolonged closing time (and jamming risk) due to the shaft structure
  • Axial disc material density = 1 (no inertia in water, light weight)
  • Spring assistance shortens closing time
  • Metal-plastic contact surface design, no impact during closing

Comparison of Pressure Fluctuations of Different Check Valves

Figure 8 shows the water hammer effect generated by different types of valves during closing under the same working conditions:

  1. Swing check valve
  2. Dual-disc check valve
  3. LIKE check valve

 LIVE VALVE Check Valve

Figure 8: Pressure Fluctuation Comparison Chart

  • Swing check valve: 34 bar
  • Dual-disc check valve: 15 bar
  • LIKE check valve: Significantly lower pressure fluctuation

Flow Coefficients (Kv, Cv)

Kv refers to the flow rate (cubic meters per hour) when water flows through the valve with a pressure loss of 1 bar at 20°C, and Cv = 1.16 × Kv.

DN (mm)

Size (inch)

Kv (Cv=1.16×Kv)

DN (mm)

Size (inch)

Kv (Cv=1.16×Kv)

DN (mm)

Size (inch)

Kv (Cv=1.16×Kv)

80

3”

171

350

14”

2312

900

36”

21378

100

4”

266

400

16”

3067

1000

40”

19319

125

5”

417

450

18”

4003

1200

48”

38451

150

6”

602

500

20”

4830

1400

56”

52549

200

8”

762

600

24”

6937

1600

64”

68635

250

10”

1186

700

28”

13091

1800

72”

86861

300

12”

1704

800

32”

12170

-

-

-

Pressure Loss (ΔP)

Simplified calculation formula:

ΔP = ρ × (Q/Kv)²

  • Definition:
  • ΔP: Pressure loss (bar)
  • ρ: Density (density of water ρ=1)
  • Q: Flow rate (cubic meters per hour)
  • Kv: Flow coefficient (cubic meters per hour)
  • Unit conversion: 10 meters of water column = 1 bar = 100 kPa = 14.5 psi

 LIVE VALVE Check Valve

Figure 9: Pressure Loss-Flow Rate Curve

  • Vertical axis: Pressure loss (meter of water column)
  • Horizontal axis: Flow rate (liters per second)
  • Curve: Pressure loss variation trend of valves with different DN specifications (DN80, DN100, DN200, DN250, DN300)

Material Selection Table

Medium

Valve Body

Axial Disc

Spring

Cold Water

Ductile Iron, Stainless Steel, Ductile Nickel Resist Alloy, Aluminum Bronze, Duplex Steel

Polytetrafluoroethylene (PTFE)

Stainless Steel, Inconel®

Hot Water

Ductile Iron, Stainless Steel, Ductile Nickel Resist Alloy, Aluminum Bronze, Duplex Steel

Polytetrafluoroethylene (PTFE)

Stainless Steel, Inconel®

Deionized Water

Ductile Iron, Stainless Steel, Ductile Nickel Resist Alloy, Aluminum Bronze, Duplex Steel

Polytetrafluoroethylene (PTFE)

Stainless Steel, Inconel®

Seawater

Ductile Iron, Stainless Steel, Ductile Nickel Resist Alloy, Aluminum Bronze, Duplex Steel

Polytetrafluoroethylene (PTFE)

Stainless Steel, Inconel®

Drinking Water

Ductile Iron, Stainless Steel, Ductile Nickel Resist Alloy, Aluminum Bronze, Duplex Steel

Polytetrafluoroethylene (PTFE)

Stainless Steel, Inconel®

Heating - HVAC

Ductile Iron, Stainless Steel, Ductile Nickel Resist Alloy, Aluminum Bronze, Duplex Steel

Polytetrafluoroethylene (PTFE)

Stainless Steel, Inconel®

Weak Acid (Low Concentration)

Ductile Iron, Stainless Steel, Ductile Nickel Resist Alloy, Aluminum Bronze, Duplex Steel

Polytetrafluoroethylene (PTFE)

Stainless Steel, Inconel®

Alcohol

Ductile Iron, Stainless Steel, Ductile Nickel Resist Alloy, Aluminum Bronze, Duplex Steel

Polytetrafluoroethylene (PTFE)

Stainless Steel, Inconel®

Oils

Ductile Iron, Stainless Steel, Ductile Nickel Resist Alloy, Aluminum Bronze, Duplex Steel

Polytetrafluoroethylene (PTFE)

Stainless Steel, Inconel®

Hydrocarbons

Ductile Iron, Stainless Steel, Ductile Nickel Resist Alloy, Aluminum Bronze, Duplex Steel

Polytetrafluoroethylene (PTFE)

Stainless Steel, Inconel®

Parts List and Dimensions

Parts List

No.

Component Name

Type

Optional Materials

Other Materials

1a/1b

Valve Body/Upstream Valve Body

Ductile Iron

EN GJS 400-15 (JS1030)

EN-GJS-350-22 (M6201)

-

-

Stainless Steel

EN GX5CrNiMo-19-11-2 (1.4408)

Z3CN20-09M (M3402)

-

-

Ductile Nickel Resist Alloy

EN GJSA-XNiCr20-2 (JS3011)

None

-

-

Aluminum Bronze

EN CuAl10Fe5Ni5-C (CC333G)

None

-

-

Duplex Steel

EN GX2CrNiMoN22-5-3 (1.4470)

GX2CrNiMoN22-5-3 (M113)

2a/2b

Back Plate/Downstream Valve Body

Ductile Iron

EN GJS 400-15 (JS1030)

EN-GJS-350-22 (M6201)

-

-

Stainless Steel

EN GX5CrNiMo-19-11-2 (1.4408)

Z3CN20-09M (M3402)

-

-

Ductile Nickel Resist Alloy

EN GJSA-XNiCr20-2 (JS3011)

None

-

-

Aluminum Bronze

EN CuAl10Fe5Ni5-C (CC333G)

None

-

-

Duplex Steel

EN GX2CrNiMoN22-5-3 (1.4470)

GX2CrNiMoN22-5-3 (M113)

3

Axial Disc[1]

Polyurethane

-

-

-

-

Polytetrafluoroethylene (PTFE)

-

-

4

Spring

Stainless Steel

-

-

-

-

Inconel®

-

-

5

O-ring

Nitrile Rubber, Ethylene Propylene Diene Monomer (EPDM)

-

-

6

Nameplate

Stainless Steel

-

-

 LIVE VALVE Check Valve

Valve Dimensions (mm) - Figure 10

DN (mm)

Size (inch)

Outer Diameter A

Outer Diameter B

Size C

Size D

Outer Diameter E

Weight (kg)

Wafer-type Valve Body

-

-

-

-

-

-

-

80

3”

90

142

80

115

132

2

100

4”

113

174

100

140

162

5.5

125

5”

138

210

125

170

192

11

150

6”

163

246

150

195

216

17

200

8”

224

290

127

256

271

22

250

10”

275

352

146

310

326

36

300

12”

323

398

181

360

376

53

350

14”

373

460

222

413

435

80

400

16”

418

520

232

460

485

100

450

18”

569

544

260

507

536

150

500

20”

518

626

292

565

590

180

Flanged-type Valve Body

-

-

-

-

-

-

-

600

24”

615

920

435

930

[2]

550

700

28”

715

1120

500

1130

[2]

875

800

32”

820

1180

515

1190

[2]

1100

900

36”

930

1480

710

1490

[2]

1600

1000

40”

1030

1500

730

1510

[2]

2050

1200

48”

1230

1890

900

1900

[2]

3400

1400

56”

1430

2265

1120

2275

[2]

5400

1600

64”

1660

2520

1352

2540

[2]

8100

1800

72”

1860

2850

1440

2890

[2]

11850

Notes

  1. The selection of axial disc material shall be determined according to application parameters. For details, please contact the manufacturer.
  2. The outer diameter and bolt hole dimensions comply with the corresponding flange standards.
  3. The dimension unit is millimeters, and the weight unit is kilograms, which are for reference only.

Installation Instructions

Maximum Working Pressure

DN (mm)

Size (inch)

Maximum Working Pressure (bar)

Maximum Working Pressure (psi)

DN (mm)

Size (inch)

Maximum Working Pressure (bar)

Maximum Working Pressure (psi)*

DN (mm)

Size (inch)

Maximum Working Pressure (bar)

Maximum Working Pressure (psi)*

DN (mm)

Size (inch)

Maximum Working Pressure (bar)

Maximum Working Pressure (psi)*

80

3”

50

725

250

10”

50

725

500

20”

50

725

1000

40”

20

290

100

4”

50

725

300

12”

50

725

600

24”

25

362

1200

48”

16

240

125

5”

50

725

350

14”

50

725

700

28”

25

362

1400

56”

16

240

150

6”

50

725

400

16”

50

725

800

32”

25

362

1600

64”

16

240

200

8”

50

725

450

18”

50

725

900

36”

20

290

1800

72”

16

240

  • Values at ambient temperature

Flange Installation Adaptation Table

Flange Standard

Pressure Class

DN Specification (inch)

EN 1092-1, DIN 2501, BS4504, ISO 2084, ISO 7005

PN6, PN10, PN16, PN25, PN40

3” - 72” (full specification adaptation)

EN1759

Class 150, Class 300

3” - 72” (full specification adaptation)

ANSI B16.5

Class 150, Class 300

3” - 20” (full specification adaptation); 24” - 72” (refer to ANSI B16.47A)

ANSI B16.47 A

Class 150

24” - 72” (full specification adaptation); 3” - 20” (refer to ANSI B16.5)

MSS SP44

Class 150

3” - 72” (full specification adaptation)

AWWA C207

Tables 2-3-4-5

3” - 72” (full specification adaptation)

LIVE VALVE Check Valve

Installation Diagrams

  • Figure 11: DN80 - DN500 (3” - 20”): Wafer-type installation (pipe flange + valve + pipe flange)
  • Figure 12: DN600 - DN1800 (24” - 72”): Flanged-type installation (convex type) (pipe flange + valve + pipe flange)
  • Figure 13: Customized on demand (DN600 - DN1800): Flanged-type installation (flat type) (pipe flange + valve + pipe flange)

General Installation Rules

  • The LIKE check valve can be installed at any angle (horizontal, vertical, inclined)
  • The product does not include flange gaskets and bolts

Storage Requirements

  • During storage, protective measures shall be taken to avoid the impact of weather, marine salt spray, dust and moisture
  • The storage environment temperature shall not be lower than -10°C (50°F)
  • No special protective measures are required for storage period exceeding 6 months

Installation Steps 

Like most valves and pipe fittings, it is recommended that the pipeline adopt a slip-on flange or similar structure to reserve sufficient installation and disassembly clearance, so as to avoid excessive stress caused by inevitable misalignment.

At least one end of the pipeline connected to the valve shall be firmly fixed to withstand the thrust generated when the valve is closed.

Preparation before startup:

  1. Carefully check the cleanliness of the valve before installation, remove possible contaminants and particles in the pipeline, and thoroughly flush the system with water or compressed air if necessary.

Important note: Special attention should be paid to removing welding slag fragments that may damage the axial disc and sealing surface.

  1. Do not weld the pipe flange after the valve is installed in place to avoid damaging the axial disc.
  2. Install grilles or filters to prevent particles from affecting the valve function.
  3. Ensure that the fluid flow direction is consistent with the arrow mark on the valve.
  4. The LIKE wafer-type valve must be accurately aligned with the pipeline center line. If necessary, use a spacer tube fixed with tie rods.

Figure 14: Pump + LIKE: Installation spacing L > 3×DN

Figure 15: Sempell Centric Butterfly Valve + LIKE: Installation spacing L > 4×DN

Figure 16: Series installation of LIKE: Spacing between adjacent valves L > 2×DN; Combination of LIKE and Sempell centric butterfly valve: Spacing L > 4×DN

图14-16 英文 拷贝.jpg

Installation Recommendations

  • Figure 14: Pump + LIKE: Installation spacing L > 3×DN
  • Figure 15: Sempell Centric Butterfly Valve + LIKE: Installation spacing L > 4×DN
  • Figure 16: Series installation of LIKE: Spacing between adjacent valves L > 2×DN; Combination of LIKE and Sempell centric butterfly valve: Spacing L > 4×DN

Order Code and Selection Guide

 生产步骤 英文 拷贝.jpg

Example 1

201 200 PN16 PS10

  • Description: LIKE check valve, valve body and matching flange material is ductile iron, axial disc is polyurethane, spring is stainless steel, DN200, adapted to EN1092 standard PN16 flange, working pressure 10 bar

Example 2

201 200 PN16 PS10 P(ACS)

  • Description: Same as Example 1, additionally obtained drinking water certification (ACS), working pressure 10 bar

Code Description

Code Segment

Meaning

Optional Parameters

Valve Body Material

201: Ductile Iron<br>202: Ductile Nickel Resist Alloy<br>203: Stainless Steel<br>204: Aluminum Bronze<br>205: Duplex Steel

-

Axial Disc[1]

3: Polyurethane, Polytetrafluoroethylene (PTFE)

-

Spring[1]

3: Standard Stainless Steel, Inconel®

-

DN Specification

80 (3”) - 1800 (72”)

-

Flange Type

The standard shall be specified (refer to page 6)

-

Working Pressure

PS + numerical value (unit: bar)

-

Valve Options

FF: Flat Type

-

Certification

P: Drinking Water Certification<br>X: ATEX Certification

-

Notes

The material selection shall be determined according to application parameters. For details, please contact the manufacturer.

© 2020 LIKE Valve (Tianjin) Co., Ltd. All rights reserved.

Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours

Leave YourMessage

Thank you! We will reply you via email within 24 hours.

Return